UK Lights Reviewed Under UL, ULC, FM, CSA, ATEX
Standards For Hazardous Locations
Ordinary flashlights can potentially cause a fire or explosion when
used in an area where the air contains small amounts of flammable
gasses like methane or particles such as grain dust or powered
aluminum. Lights rated for use in these "Hazardous Locations" should be
used. A considerable amount of effort has been expended to define
exactly what these locations are and how electrical equipment should be
built and tested for use in Hazardous Locations. In the US the defining
document is the National Electric Code (NFPA 70). Testing Laboratories
such as UL, FM and CSA (Canada) have created standards and tests
specifically for the use of flashlights used in the Hazardous Locations
laid out in the NEC. Although no specific standard exists in the
European Union (EU) for flashlights ratings are applied relative to
general standards for use of electrical equipment in Hazardous
Locations.
When choosing a flashlight it is extremely important that the
rating applied to the flashlight be understood and the light not be
used in areas which exceed the rating of the flashlight. The ratings
reveal the type of gas mixture allowed, the temperature of the hottest
element in the light and list the specific brand and model number of
battery permitted.
The standards and tests used to rate flashlights are listed below. They
are readily available from standards resellers on the internet.
American Standards
NFPA 70 National Electric Code
ANSI/UL 783 - 6th Edition Electric Flashlights and Lanterns for Use in Hazardous Locations
UL 1604 - 3rd Edition Electrical Equipment for Use in Class I and II, Division 2 and Class III Hazardous Locations
FM 3600 Electrical Equipment for use in Hazardous Locations, General Requirements
FM 3613 Electrical Flashlights and Lanterns for Use in Class I, Division 2, Class I, Zone 2 Hazardous Locations
FM 3606 Repair Service for Process Control Equipment Used in hazardous Locations
FM 3611 Electrical Equipment for Use in Class I, Div.2, Class II, Div.2 and Class III, Divisions 1 and 2 Hazardous Locations
CSA Std C22.2 No. 213-M1987 Non-incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
IEC 529 Degree of Protection Porvided by Enclosures
European Standards
European Union Directive 94/9/EC or 23 March 1994 (Annex II)
EN 50021 : 1999 - Type of protection "n"
EN 50014 : 1997 + A1 + A2 - General Requirements
EN 50020 : 1994 - Intrinsic Safety "i"
EN 50020 : 2002 - Intrinsic Safety "i"
EN 50019 : 1994 - Increased Safety "e"
EN 60079-0 : 2006 - General requirements
EN 60079-7 : 2007 - Type of protection "e"
EN 60079-11 : 2007 - Type of protection "i"
EN 60079-15 : 2007 - Type of protection "n"
EN 1127-1 : 2007
Testing Laboratories
UL, ULC - Underwriters Laboratories Inc.
FM - FM Global
CSA - Canadian Standards Association
SNCH - Société Nationale de Certification et d'Homologation
SEV - Electorsuisse
UK Lights Rated for Use in Hazardous Locations
UK2AAA Mini Pocket Light (ATEX)
Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIC T4 USE ONLY WITH 09801 LAMP UK2AAA Mini Pocket Light (UL, ULC)
CL I,D2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C. UL Listed (Canada) CL I, DIV 2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C. USE ONLY WITH 09801 OR 09802 LAMP TEMP CODE T3A FOR 09801. UK2AAA Pen Light (ATEX)
Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIC T4 USE ONLY WITH 09801 LAMP UK2AAA Pen Light (UL, ULC)
CL I, DIV 2 GP A, B, C, D; CL II DIV 2 GP G, USE ONLY WITH 09801 OR 09802 LAMP TEMP CODE T3A FOR 09801 LAMP UK2AAA Pen Light S (UL, ULC)
CL I, DIV 2 GP A, B, C, D; CL II DIV 2 GP G, USE ONLY WITH 09801 OR 09802 LAMP TEMP CODE T3A FOR 09801 LAMP UK2AAA Pen Light S (ATEX)
Zone 1 SNCH 05 ATEX 3807 II 3G EEx nA II T5 USE ONLY WITH 09801 LAMP UK300 (UL, ULC, FM, CSA, ATEX)
Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIB T5 UL Listed (U.S. only) CL I, DIV 2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C. UL Listed (U.S. and Canada) CL I, DIV 2, GP A, B, C, D; CL II, DIV 2 GP G TEMP CODE T3C. USE ONLY WITH 22806 LAMP. FM, CSA Approved CL I, DIV 2 GP A, B, C, D, TEMP CODE T3C; CLII, DIV 2, GP F,G CLIII, DIV 2, TEMP CODE T4 UK4AA-ES (ATEX)
Zone 1 SEV 08 ATEX 0164 II 2G Ex e ib IIC T4 II 2D Ex ibD 21 T98°C USE ONLY WITH 14806 LAMP UK4AA-EN (ATEX)
Zone 1 SEV 08 ATEX 0164 II 2G Ex e ib IIC T4 II 2D Ex ibD 21 T98°C USE ONLY WITH 14806 LAMP |
UK4AA-AS2 (UL, ULC, FM, CSA)
CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A FM, CSA Approved CL I, DIV 2 GP A, B, C, D, T2 CLII, DIV 2, GP F, G, CLIII, DIV 2, T3C USE ONLY WITH 14801 LAMP UK4AA-AS2 Unilite (4AA Right Angle Light) (UL, ULC)
CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A USE ONLY WITH 14801 LAMP UK4AA-AN2 (UL, ULC, FM, CSA)
CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A FM, CSA Approved CL I, DIV 2 GP A, B, C, D, T2 CLII, DIV 2, GP F, G, CLIII, DIV 2, T3C USE ONLY WITH 14801 LAMP UK4AA-AS2R (UL, ULC)
CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2B USE ONLY WITH 14824, 14801, 14806 or 14830 LAMP UK4AA-AS2ZM (UL, ULC, CSA)
CSA Approved CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP F, G, CL III, DIV 2 T4 USE ONLY WITH 14846 LAMP UK4AA eLED ZOOM (ATEX)
Zone 1 SEV 08 ATEX 0164 II 2G Ex e ib IIC T4 II 2D Ex ibD 21 T98°C USE ONLY WITH 14806 LAMP UK4AA-ET (ATEX)
Zone 1 SEV 08 ATEX 0164 II 2G Ex e ib IIC T4 II 2D Ex ibD 21 T98°C USE ONLY WITH 14806 LAMP< UK2AA-AS1 (UL, CSA)
CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T3C CSA Approved CL I, DIV 2 GP A, B, C, D, T3A CLII, DIV 2, GP F, G, CLIII, DIV 2 USE ONLY WITH 15801 LAMP |