SAFETY APPROVALS

UK Lights Reviewed Under UL, ULC, FM, CSA, ATEX
Standards For Hazardous Locations

Ordinary flashlights can potentially cause a fire or explosion when used in an area where the air contains small amounts of flammable gasses like methane or particles such as grain dust or powered aluminum. Lights rated for use in these "Hazardous Locations" should be used. A considerable amount of effort has been expended to define exactly what these locations are and how electrical equipment should be built and tested for use in Hazardous Locations. In the US the defining document is the National Electric Code (NFPA 70). Testing Laboratories such as UL, FM and CSA (Canada) have created standards and tests specifically for the use of flashlights used in the Hazardous Locations laid out in the NEC. Although no specific standard exists in the European Union (EU) for flashlights ratings are applied relative to general standards for use of electrical equipment in Hazardous Locations.

When choosing a flashlight it is extremely important that the rating applied to the flashlight be understood and the light not be used in areas which exceed the rating of the flashlight. The ratings reveal the type of gas mixture allowed, the temperature of the hottest element in the light and list the specific brand and model number of battery permitted.

The standards and tests used to rate flashlights are listed below. They are readily available from standards resellers on the internet.

American Standards

NFPA 70 National Electric Code

ANSI/UL 783 - 6th Edition Electric Flashlights and Lanterns for Use in Hazardous Locations
UL 1604 - 3rd Edition Electrical Equipment for Use in Class I and II, Division 2 and Class III Hazardous Locations

FM 3600 Electrical Equipment for use in Hazardous Locations, General Requirements
FM 3613 Electrical Flashlights and Lanterns for Use in Class I, Division 2, Class I, Zone 2 Hazardous Locations
FM 3606 Repair Service for Process Control Equipment Used in hazardous Locations
FM 3611 Electrical Equipment for Use in Class I, Div.2, Class II, Div.2 and Class III, Divisions 1 and 2 Hazardous Locations

CSA Std C22.2 No. 213-M1987 Non-incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
IEC 529 Degree of Protection Porvided by Enclosures

European Standards

European Union Directive 94/9/EC or 23 March 1994 (Annex II)
EN 50021 : 1999 - Type of protection "n"
EN 50014 : 1997 + A1 + A2 - General Requirements
EN 50020 : 1994 - Intrinsic Safety "i"
EN 50020 : 2002 - Intrinsic Safety "i"
EN 50019 : 1994 - Increased Safety "e"
EN 60079-0 : 2006 - General requirements
EN 60079-7 : 2007 - Type of protection "e"
EN 60079-11 : 2007 - Type of protection "i"
EN 60079-15 : 2007 - Type of protection "n"
EN 1127-1 : 2007

Testing Laboratories

UL, ULC - Underwriters Laboratories Inc.
FM - FM Global
CSA - Canadian Standards Association
SNCH - Société Nationale de Certification et d'Homologation
SEV - Electorsuisse


UK Lights Rated for Use in Hazardous Locations


UK2AAA Mini Pocket Light (ATEX)
    Zone 2 SEE 00 ATEX 3096 II 3G EEx nC II T5
    Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIC T4
    USE ONLY WITH 09801 LAMP

UK2AAA Mini Pocket Light (UL, ULC)
    UL Listed (U.S. only)
    CL I,D2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C.
    UL Listed (Canada)
    CL I, DIV 2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C.
    USE ONLY WITH 09801 OR 09802 LAMP TEMP CODE T3A FOR 09801.

UK2AAA Pen Light (ATEX)
    Zone 2 SEE 00 ATEX 3096 II 3G EEx nC II T5
    Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIC T4
    USE ONLY WITH 09801 LAMP

UK2AAA Pen Light (UL, ULC)
    UL Listed (U.S. and Canada)
    CL I, DIV 2 GP A, B, C, D; CL II DIV 2 GP G, USE ONLY WITH 09801 OR 09802 LAMP
    TEMP CODE T3A FOR 09801 LAMP

UK2AAA Pen Light S (UL, ULC)
    UL Listed (U.S. and Canada)
    CL I, DIV 2 GP A, B, C, D; CL II DIV 2 GP G, USE ONLY WITH 09801 OR 09802 LAMP
    TEMP CODE T3A FOR 09801 LAMP

UK2AAA Pen Light S (ATEX)
    Zone 2 SNCH 05 ATEX 3806 II 2G EEx ib e IIC T5
    Zone 1 SNCH 05 ATEX 3807 II 3G EEx nA II T5
    USE ONLY WITH 09801 LAMP

UK300 (UL, ULC, FM, CSA, ATEX)
    Zone 2 SEE 00 ATEX 3096 II 3G EEx nC II T5
    Zone 1 SEE 00 ATEX 2931 II 2G EEx ia IIB T5

    UL Listed (U.S. only)
    CL I, DIV 2, GP A, B, C, D CL II, DIV 2 GP G TEMP CODE T3C.

    UL Listed (U.S. and Canada)
    CL I, DIV 2, GP A, B, C, D; CL II, DIV 2 GP G TEMP CODE T3C.
    USE ONLY WITH 22806 LAMP.

    FM, CSA Approved
    CL I, DIV 2 GP A, B, C, D, TEMP CODE T3C; CLII, DIV 2, GP F,G CLIII, DIV 2, TEMP CODE T4

UK4AA-ES (ATEX)
    Zone 2 Certifications for Zone 1 include Zone 2
    Zone 1 SEV 08 ATEX 0164
    II 2G Ex e ib IIC T4
    II 2D Ex ibD 21 T98°C
    USE ONLY WITH 14806 LAMP

UK4AA-EN (ATEX)
    Zone 2 Certifications for Zone 1 include Zone 2
    Zone 1 SEV 08 ATEX 0164
    II 2G Ex e ib IIC T4
    II 2D Ex ibD 21 T98°C
    USE ONLY WITH 14806 LAMP



  UK4AA-AS2 (UL, ULC, FM, CSA)
    UL (US, Canada) Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A

    FM, CSA Approved
    CL I, DIV 2 GP A, B, C, D, T2 CLII, DIV 2, GP F, G, CLIII, DIV 2, T3C
    USE ONLY WITH 14801 LAMP

UK4AA-AS2 Unilite (4AA Right Angle Light) (UL, ULC)
    UL (US, Canada) Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A
    USE ONLY WITH 14801 LAMP

UK4AA-AN2 (UL, ULC, FM, CSA)
    UL (US, Canada) Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2A

    FM, CSA Approved
    CL I, DIV 2 GP A, B, C, D, T2 CLII, DIV 2, GP F, G, CLIII, DIV 2, T3C
    USE ONLY WITH 14801 LAMP

UK4AA-AS2R (UL, ULC)
    UL (US, Canada) Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T2B
    USE ONLY WITH 14824, 14801, 14806 or 14830 LAMP

UK4AA-AS2ZM (UL, ULC, CSA)
    UL (US, Canada) Approved
    CSA Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP F, G, CL III, DIV 2 T4
    USE ONLY WITH 14846 LAMP

UK4AA eLED ZOOM (ATEX)
    Zone 2 Certifications for Zone 1 include Zone 2
    Zone 1 SEV 08 ATEX 0164
    II 2G Ex e ib IIC T4
    II 2D Ex ibD 21 T98°C
    USE ONLY WITH 14806 LAMP

UK4AA-ET (ATEX)
    Zone 2 Certifications for Zone 1 include Zone 2
    Zone 1 SEV 08 ATEX 0164
    II 2G Ex e ib IIC T4
    II 2D Ex ibD 21 T98°C
    USE ONLY WITH 14806 LAMP<

UK2AA-AS1 (UL, CSA)
    UL (US) Approved
    CL I, DIV 2, GP A, B, C, D, CL II, DIV 2 GP G, CL III, DIV 2 T3C

    CSA Approved
    CL I, DIV 2 GP A, B, C, D, T3A CLII, DIV 2, GP F, G, CLIII, DIV 2
    USE ONLY WITH 15801 LAMP